Trace hydrocarbon analyzer

Trace hydrocarbon analyzer
Product Detailed
Related Categories:Gas Analyzers
trace hydrocarbon analyzer 1.Automatically sampling and injecting 2.Clinical chemistry 3.On-line

trace hydrocarbon analyzer1.Automatically sampling and injecting2.Clinical chemistry3.On-line 

Trace hydrocarbon analyzerAs a process control instrument for the detecting of carbon hydrocarbons in the petroleum, chemical industry, steel industry, gas industry and other industries, GS-101 A has a high separation efficiency for those substances (C1 to C4) which are hard to separate, and has a high detecting sensitivity (0.01ppm for ethyne). It is compliant with related standards in Chinese National Standards.

Description:

GS-101A, an automatic trace amount hydrocarbon online detecting chromatograph, could quantitative analyze trace amount hydrocarbon in liquid oxygen, CO2 and other inert gas. It can be connected directly to the producing equipment to inspect the change of component contents at any moment, providing important data for the safe operation of main condenser of air separation unit.

Meanwhile, as a process control instrument for the hydrocarbon detection in the petroleum, chemical industry, steel industry, gas industry and other industries, it has a high separation efficiency for those substances (C1 to C4) which are hard to separate, and has a high detecting sensitivity (0.01ppm for ethyne). It is compliant with related standards in Chinese National Standards.

The instrument samples, injects, outputs analysis report automatically. The three circuit lines of liquid air/liquid oxygen/product oxygen are detected automatically. Single line detection could also be done. It has been already widely applied in oxygen generation from air separation.

Performance Characteristics:

«  Automatically sampling and injecting. Multi-point (2-8) cycling-detection and single point detection

    are both applicable. Unattended operation applicable.

«  Specialized column with long lifetime and short analysis period (single detecting time less than   

    5min)

«  Detector with high sensitivity and low noise.

«  Automatically sampling and injection valve with novelty structure and long lifetime (more than

    100000 times using without damage)

«  Intelligent temperature controller to control the temperature. The temperature of any line exceeds the 

    limits would cause an alarm and automatically power off protecting.

Technical Parameters:

«        System stabilization time: <1.0 h

«        Temperature precision: ± 0.1 oC

«        Temperature range: RT +5 ~ 350 °C

«        Baseline drift: ≤ 1×10-11 A/30min

«        Baseline noise: ≤1×10-12A

Detecting Concentrations:

Components                    detection limits (ppm)

Methane                           ≥ 0.01

Ethane                             ≥ 0.01

Ethylene                            ≥ 0.01

Acetylene                          ≥ 0.01

Propane                            ≥ 0.02

Propylene                          ≥ 0.02

N-butane                            ≥ 0.02

Isobutane                           ≥ 0.02

Butadiene                          ≥ 0.02

Instrument Dimension:                600mm * 500mm * 450mm

Weight:                       37 KGS